6. MESSAGES - AUDIO
6.1 Volume
This command is used to set/get the Volume as it is defined as below.
6.1.1 Message-Get
Bytes Bytes Description Bits Description
DATA[0] 0x45 = Volume
Get
Command requests the display to report its current
Volume level
The interface to set Software must be such that they also modify the variables representing these
current parameters.
To mute the display, send Volume = 0. This command does not overwrite the system mute status of
the display.
Example: (Display address 01)
Header
Monitor
ID
Category
Code0
Code1
Length
Data
Control
Data[0]
Checksum
0xA6 0x01 0x00 0x00 0x00 0x03 0x01 0x45 0xE0
6.1.2 Message-Report
Bytes Bytes Description Bits Description
DATA[0]
0x45 = Volume
Report
Command reports current Volume level
DATA[1] Volume. 0 to 60 of the user selectable range of the display.
Example: Current Display settings: Volume:50 (0x32) (Display address 01)
Header
Monitor
ID
Category
Page
Length
Control
Data[0]
Data[1]
Checksum
0x21 0x01 0x00 0x00 0x04 0x01 0x45 0x32 0x52
6.1.3 Message-Set
Bytes Bytes Description Bits Description
DATA[0] 0x44 = Volume – Set
DATA[1]
Volume.
0 to
60
of the user selectable range of the display.
Example: Set the Display Volume to 20 (0x14) (Display address 01)
Header
Monitor
ID
Category
Code0
Code1
Length
Data
Control
Data[0]
Data[1]
Checksum
0xA6 0x01 0x00 0x00 0x00 0x04 0x01 0x44 0x14 0xF2